HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS REGISTER
[Advanced]

Published Online First: 4 May 2007. doi:10.1136/hrt.2006.106369
Heart 2008;94:53-58
Copyright © 2008 BMJ Publishing Group Ltd & British Cardiovascular Society

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
hrt.2006.106369v1
94/1/53    most recent
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this link to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Add article to my folders
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lane, R E
Right arrow Articles by Chow, A W C
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lane, R E
Right arrow Articles by Chow, A W C
Topic Collections
Right arrowRelevant Article

HEART FAILURE AND CARDIOMYOPATHY

Comparison of temporary bifocal right ventricular pacing and biventricular pacing for heart failure: evaluation by tissue Doppler imaging

R E Lane1, J Mayet1, N S Peters1, D W Davies1, A W C Chow1,2

1 Waller Cardiac Unit, International Centre for Circulatory Health, St Mary’s Hospital and Imperial College of Medicine, London, UK
2 The Heart Hospital, UCLH, Westmoreland Street, London, UK

Correspondence to:
Dr Anthony W C Chow, The Heart Hospital, 16–18 Westmoreland Street, London W1G 8PH, UK; anthony.chow{at}uclh.nhs.uk


ABSTRACT
Background: The complications and limitations of biventricular pacing largely relate to left ventricular (LV) pacing. An alternative approach was tested of simultaneously pacing the right ventricular (RV) apex and outflow tract (RVOT) or using bifocal right ventricular pacing (BRVP) to provide cardiac resynchronisation.

Methods: 21 consecutive patients with heart failure and severely impaired left ventricular function were studied. Ejection fraction and tissue Doppler data were collected at baseline, during BRVP, and during biventricular pacing, using a temporary pacing protocol.

Results: BRVP was achieved in all patients without complication. BRVP significantly reduced mean baseline intra-LV, inter-LV–RV, and global mechanical dyssynchrony from (mean (SD)) 71 (35) to 44 (18) ms, p = 0.003; 86 (42) to 57 (33) ms, p = 0.029; and 157 (67) to 101 (42) ms, p = 0.005, respectively. It increased the ejection fraction from 21 (8)% to 29 (7)%, p = 0.002. Compared with BRVP, reductions in intra-LV, inter-LV–RV, and global mechanical dyssynchrony were superior with biventricular pacing (31 (12) ms, p = 0.014; 36 (27) ms, p = 0.008; and 67 (34) ms, p = 0.01 compared with BRVP, respectively); improvements in ejection fraction were similar (26 (9)%, NS).

Conclusions: In patients with heart failure, superior mechanical resynchronisation is achieved with biventricular pacing compared with BRVP. BRVP may be useful when left ventricular lead placement is not possible.


Keywords: biventricular pacing; bifocal right ventricular pacing; ventricular dyssynchrony; tissue Doppler imaging


Relevant Article

Pacing in heart failure: how many leads and where?
S Serge Barold and Bengt Herwerg
Heart 2008 94: 10-12. [Extract] [Full Text] [PDF]



This article has been cited by other articles:


Home page
HeartHome page
S S. Barold and B. Herwerg
Pacing in heart failure: how many leads and where?