Article Text

Download PDFPDF
Transcatheter closure of ventricular septal defect using detachable steel coil

Abstract

Transcatheter closure has been attempted in selected cases of ventricular septal defects using Lock clamshell device, Rashkind umbrella device, and Sideris buttoned device. A small perimembranous ventricular septal defect with aneurysm of membranous septum in a 12 year old girl was closed successfully with a detachable steel coil of 8 mm diameter with four loops, after failure of deployment of a Rashkind double umbrella device.

  • transcatheter closure
  • ventricular septal defect
  • septal aneurysm
  • detachable coil
  • congenital heart defects

Statistics from Altmetric.com

Request Permissions

If you wish to reuse any or all of this article please use the link below which will take you to the Copyright Clearance Center’s RightsLink service. You will be able to get a quick price and instant permission to reuse the content in many different ways.